Filter Solutions Under One Roof
Technology for Hydraulic and lubrication applications
Pressure Line Filter
Working Pressure up to 160barFor specific component protection contributes to overall system cleanliness level. Catches wear debris from pump

Model |
HPF45 |
HPF75 |
HPF115 |
HPF175 |
HPF250 |
HPF350 |
HPF475 |
HPF700 |
HPF1000 |
End Connections (BSP/SAE Flange) |
G½ " |
G1/2", 3/4" |
G3/4", 1" |
G 1, 1 ½, |
G1, 1 ½ |
G1 ¼, 1 ½, |
G 1 ½ SAE2" |
SAE2" |
SAE2" |
Nominal Flow (LPM) |
45 |
75 |
115 |
175 |
250 |
350 |
475 |
700 |
1000 |
Duplex Filters
Working Pressure Upto 160barService & replacement of Filter Elements without interrupting the system

Model |
HDF45 |
HDF75 |
HDF115 |
HDF175 |
HDF250 |
HDF350 |
HDF475 |
HDF700 |
HDF1000 |
End Connections BSP/SAE Flange |
G½ " |
G1/2", 3/4" |
G3/4", 1" |
G 1", 1 ½:, |
G1", 1 ½" |
G1 ¼", 1 ½", |
G 1 ½"
|
SAE2" |
SAE3" |
Nominal Flow(LPM) |
45 |
75 |
115 |
175 |
250 |
350 |
475 |
700 |
1000 |
Return Line ( Tan Top )
Working Pressure Upto 10barCatches wear from total system components & restrict the entry into the reservoir.

Model |
TTF45 |
TTF75 |
TTF115 |
TTF175 |
TTF250 |
TTF350 |
TTF475 |
TTF700 |
TTF1000 |
End Connections BSP/SAE Flange |
G½ " |
G1/2" , 3/4" |
G3/4", 1" |
G 1, 1 ½, |
G1, 1 ½ |
G1 ¼, 1 ½, |
G 1 ½
|
G1 ½, SAE2" |
SAE2" |
Nominal Flow(LPM) |
45 |
75 |
115 |
175 |
250 |
350 |
475 |
700 |
1000 |
Off Line Filters
Working Pressure Upto 5barOffline filtration enables continuous, multi-pass filtration at a controlled flow velocity and pressure drop, which results in high filtering efficiency.

Model |
HOF115 |
HOF175 |
HOF225 |
HOF275 |
HOF350 |
HOF475 |
HOF700 |
HOF1000 |
HOF1250 |
End BSP/SAE Flange |
G1 " |
G1" |
G1", 1 1/4" |
G 1 ¼", 1 ½", |
G1 ½" |
G1 ½", 2" |
G 1 ½ SAE2" |
SAE2" |
SAE2" |
Nominal Flow(LPM) |
115 |
175 |
225 |
275 |
350 |
475 |
700 |
1000 |
1250 |
Oil Filteration Units
Specific & continuous fluid cleaning without interrupting the main system, irrespective of main system in operation or in shut down condition
Stationery - For Oil filtration, recirculation & transfer
Model |
HUS25 |
HUS50 |
HUS100 |
HUS150 |
End Connections (BSP/SAE Flange) |
G1 ¼", 1 ½", |
G 1 ½"
|
G1 ½", 2" |
SAE2" |
Pump Flow(LPM) |
25 |
50 |
100 |
150 |
Mobile - For Oil Filtration, Filling & Transfer.
Model |
HUM25 |
HUM50 |
HUM100 |
HUM150 |
Pump Flow(LPM) |
25 |
50 |
100 |
150 |
Element Nominal Flow (LPM) |
275 |
350 |
475 |
1000 |
Suction Strainers
To protect the Suction Pump
Model |
HSS25 |
HSS40 |
HSS60 |
HSS90 |
HSS170 |
HSS200 |
HSS300 |
HSS400 |
HSS600 |
End Connections (BSP) |
G ½ " |
G 3/4" |
G 1" |
G 1 ¼ " |
G 1 ½" |
G 2" |
G 2 ½"
|
G3" |
G3" |
Nominal Flow(LPM) |
25 |
40 |
60 |
90 |
170 |
200 |
300 |
400 |
600 |
Air Breather
For clean reservoir breathes
Model |
HBF500 |
HBF1200 |
HBF1800 |
HBF3500 |
HFB 650 Screw Type |
End Connections |
1" |
1 ½" |
2" |
3" |
50 NB |
Nominal Air Flow @ ?p =10mbar |
500 |
1200 |
1800 |
3500 |
650 ?p =.01bar |
Silica Gel Breathers
For removal of solid particles and absorption of moisture before ingested in the system
Model |
HSB105 |
HSB120 |
HSB125 |
HSB150 |
HSB155 |
Inlet - Connection (BSP) |
G1" |
G1 ½" |
G1 ½" |
G 2" |
G 2" |
Outlet - Connection (BSP |
¾" |
¾" |
1" |
1" |
1 ½" |
Max.Air Flow( m³/min.) |
1.05 |
1.25 |
1.25 |
1.50 |
1.50 |
All Filters

Pressure Line Filter
For specific component protection contributes to overall system cleanliness level. Catches wear debris from pump
Duplex Filter
Service & replacement of Filter Element without interrupting the system
Return Line ( Tan Top )
Catches wear from total system components & restrict the entry into the reservoir.
Off Line Filters
Offline filtration enables continuous, multi-pass filtration at a controlled flow velocity and pressure drop, which results in high filtering efficiency
Oil Filteration Units
Stationary and Mobile Oil Filteration Units
Suction Strainers
To protect the Suction Pump
Air Breather
For clean reservoir breathes.
Silica Gel Breathers